EU Cookie Consent

We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read Privacy Policy

Avante True 12T Twelve-Channel EKG Machine with Touch Screen

Avante True 12T Twelve-Channel EKG Machine with Touch Screen

Brand: Avante
Web ID: 1236
Product Number: 60136T(RS)

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

Avante True ECG 12T EKG Machine -Excellent Cost Performance with Large Touch Screen Display

  • Preview report for both real-time ekg printing and file storage
  • Average template ekg machine waveform with accurate interpretation tested with CSE DATABASE, which supplies measurement, diagnosis, and Minnesota code
  • Doctor can edit the ekg printing style, printing speed, sensitivity, and used filter to get better waveforms instead of repeating patient examination
  • Freeze and review waveform timely to grasp every arrythmia
  • Internal storage including waveforms, measurement and diagnosis which could also be enlarged by flash disk or PC hard disk.
  • Features 8.4" color touch-screen
  • Compact, lightweight design with carrying handle
  • Digital filters for baseline, AC and EMG interference resistence
  • Standby mode for energy saving
  • EKG Machine has Built-in Ethernet and RS-232 interfaces for PC connection
  • USB port for data transmission and external jet-printer connection
  • Internal Memory - 200 Tests
  • Built-in rechargeable Li-ion battery: voltage=14.4V - 5 hours, 400 Reports, 320 × 240 dots monochrome LCD

Specifications

General

  • Input circuit: Defibrillation protection built-in
  • Lead: Standard 12 leads
  • Acquisition mode: 12-channel simultaneous
  • A/D converter: 24 bits
  • Input voltage range: ±5mVp-p
  • Time constant:: >3.2s
  • Frequency response: 0.05Hz-150Hz
  • Calibration voltage: 1mV±2%
  • Sensitivity: 2.5, 5, 10, 20, 10/5, AGC (mm/mV)
  • Input impedance: >50M Ω (10Hz)
  • Input circuit current: <10nA
  • Noise level: <12.5 μ Vp-p
  • Patient leakage current: <10 μ (220V-240V)
  • Patient auxiliary current: <0.1 μ A (DC)
  • Filters:
    • EMG filter 25Hz/35Hz/45Hz/OFF
    • Anti-baseline drift 0.05/0.15/0.25/0.5Hz
    • Low-pass filter 150Hz/100Hz/ 75Hz
    • AC filter 50Hz/60Hz
  • CMRR >121 dB
  • Recording modes Auto/manual/rhythm
  • Rhythm lead Single lead or three leads selectable
  • Safety Standard IEC I/CF
  • Power supply AC:100-240V, 50/60Hz
  • Battery Built-in rechargeable Li-ion battery: voltage=14.4V, for about 400 copies ECG printing
  • Recorder Thermal printer
  • Recording paper Roll and z-fold 216mm, 210mm width
  • Recording speed 5mm/s, 10mm/s12.5mm/s, 25mm/s,50mm/s (±3%)
  • Dimensions 420mm × 330mm × 120mm
  • Display 800 × 600 dots LCD
  • External input >100K Ω, sensitivity 10mm/V±5
  • External output
  • Communication interface Ethernet or RS232

Videos