EU Cookie Consent
We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read Privacy Policy
0 Artículo está en su carrito Ver carrito ahora
Biomedical HTM Customers
Service, Repair & Parts
Términos y Condiciones del Listado
All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.
Instant Response technology provides surgeons with improved performance or lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to "turn up the generator."
The Force EZ generator adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag.
Capacitive coupling is reduced by 30-50% when using Instant Response technology. This reduction is achieved by limiting the RMS voltage and the high frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.
Instant Response technology features an advanced feedback system that recognizes changes in tissue 200 times per second, and adjusts voltage and current accordingly to maintain appropriate power. This unique capability differentiates Instant Response generators by their high power efficiency rating (PER). That's smart generator technology.
PER indicates the ability of a generator to accurately deliver the selected power into a wide range of tissue types. With a PER of 97, the Force EZ generator provides a consistent surgical effect.
The Force EZ generator provides surgeons with the advantage of accurately delivering the selected power setting, even through resistant tissue. The power curve below illustrates the Force EZ generator's consistent output.
When a conventional generator encounters tissue changes, both power delivery and cutting efficiency are reduced. This means that higher power settings are required in order to cut through all types of tissue. With higher power setting, more energy is delivered and tissue damaging increases.
Output power changes by less than 15% or 5 watts, whichever is greater, as the line voltage varies from 90-135 volts (into a 300 ohm load).
Source current, patient leads, all outputs tied together.
Agree with actual power into rated load to within ± 15% or 5 watts, whichever is greater. Dosage error monitor.
PER (Power Efficiency Rating) is the measure of an electrosurgical generator's ability to accurately deliver the selected power into a wide range of tissue types.
Bovie Connecting Cord for Split Adult Return Electrode P00894
Web ID:
1950
|
Bovie Disposable Solid Adult Return Electrode, Box of 50 P00910
Web ID:
1954
|
|
Bovie Disposable Solid Adult Return Electrode, Box of 50 P00085.50
Web ID:
1955
|
|
Bovie Disposable Split Adult Return Electrode, Box of 50 P00985
Web ID:
1957
|
|
Bovie Disposable Split Adult Return Electrode, Box of 50 P00084
Web ID:
1958
|
Bovie Reusable Non-Sterile Push Button Cautery Pencil P01147
Web ID:
1984
|
|
Avante Disposable Monopolar Handswitching Pencil (50/Box) P00507.50
Web ID:
2089
|
Bovie Disposable Sterile Blade ESU Electrodes
Web ID:
1962
|
|
Bovie Reusable Non-Sterile Blade ESU Electrodes
Web ID:
1981
|
|
Bovie Disposable Sterile Needle ESU Electrodes
Web ID:
1966
|
|
Bovie Disposable Sterile Supercut Tungsten Needle ESU Electrodes
Web ID:
1968
|
|
Bovie Reusable Non-Sterile Needle ESU Electrodes
Web ID:
1983
|
|
Bovie Reusable Non-Sterile Supercut Tungsten Needle ESU Electrodes
Web ID:
1986
|
|
Bovie Disposable Sterile Ball ESU Electrodes
Web ID:
1961
|
|
Bovie Reusable Non-Sterile Ball ESU Electrodes
Web ID:
1980
|
|
Bovie Disposable Sterile LLETZ Loop ESU Electrodes
Web ID:
1964
|
|
Bovie Reusable Non-Sterile Short Tungsten Loop ESU Electrodes
Web ID:
1985
|
|
Sklar Disposable Sterile Lletz Loop ESU Electrodes
Web ID:
3201
|