Economico, control sobre el terreno sistema portátil, continua, oximetría de pulso de monitoreo con alarmas y una batería interna recargable.

Specifications

Physical Weight & Dimensions

  • Height: 7.25 inches (18.4 cm)
  • Width: 3.3 inches (8.4 cm)
  • Depth: 1.85 inches (4.7 cm)
  • Weight: 19 oz. (539 grams)

Power

  • AC Power: 105-125V ~ 60Hz
  • Optional: 207-253V ~ 50Hz, 90-110V ~ 50Hz
  • Battery Standard: NiMH (Nickel Metal Hydride)
  • Battery Life: Internal rechargeable, not user replaceable. Fully charges in about 6 hours. Approximately 24 hours of continuous use.

Environment

  • Operating Temperature: -4°F to 131°F (-20°C to 55°C)
  • Storage Temperature: -40°F to 167°F (-40°C to 75°C)
  • Relative Humidity (non-condensing): 10-95% (storage); 15-95% (operating)

Displays, Indicators & Keys

  • SpO2: LED numeric display 0.43 inches (11 mm) high
  • Pulse Rate: LED numeric display 0.375 inch (9.5 mm) high
  • Pulse Strength: Logarithmically scaled 8-segment LED bar graph
  • Low Battery: LED flashes when approximately 30 minutes of battery life remains
  • Alarm Silence: LED flashes or lights to remind the user that audio alarms are disabled
  • Sensor: LED flashes to alert the operator to check the SpO2 sensor placement

SpO2

  • Range: 0-100%
  • Accuracy: ±2% at 70-100%; ±3% at 50-69%
  • Averaging: 4, 8, or 16 pulse beat average
  • Alarm Range: High - 50%-100% & OFF (1% steps) Low - OFF & 50%-99% (1% steps)

Pulse Rate

  • Range: 30-254 bpm
  • Accuracy: ±2% at 30-254 bpm
  • Resolution: 1 bpm
  • Alarm Range: High - 5-250 bpm & OFF (5 bpm steps) Low - OFF & 5-250 bpm (5 bpm steps)

Memory

Spot checks and trends can be stored for up to 99 patients and 24 hours of run time.

Auxiliary Serial Printer/Computer Output:

Data saved every thirty seconds can be printed or downloaded to a PC (trend). Data saved every four seconds in sleep mode can be output and processed by commercially available sleep study software.

Mechanical Durability Test Results

  • Vibration Testing: In compliance with IEC 68-2-6, IEC 68-2-34
  • Shock Testing: In compliance with IEC 68-2-27
  • Drop Testing: Exceeded UL 544 testing recommendations
  • Standards: EN60601-1, EN60601-1-2, CSA Std. C22.2 No. 125, UL 544
  • Regulatory Compliance: 510(k): K945754; ISO 9001/ISO 13485