An excellent cost-effective EKG machine for hospitals, family practices and emergency responders.

Features

  • Portable, lightweight design - Convenient for mobile use and offices with limited space
  • Easy data input and operation - Alphanumeric keyboard and one-touch operation
  • Power supply - Built-in rechargeable battery, AC/DC power supply
  • Pacemaker detection - Meets the requirements of ANSI/AAMI EC11
  • EKG / ECG Interpretation - Automatic measurement and interpretation for adults and pediatrics
  • Periodic recording - Two-step exercise test with periodic recording
  • Heart rate variability (HRV) analysis
  • Recording - Internal thermal printer and external printer
  • Memory and data transmission - SD card and card reader, and flash drive (not included)
  • Data transmission to PC via Ethernet or RS232 port

Options

  • Internal storage upgrade to 200 ECGs
  • PC-based data managementsoftware (Smart ECG Viewer)
  • XML format export
  • SD card and card reader, flash disk
  • Rolling stand and carrying bag

Specifications

General

  • Input circuit: Defibrillation protection
  • Lead: Standard 12 leads
  • Acquisition mode: 12-channel simultaneous (10-24s adjustable)
  • A/D converter: 24 bits
  • Sampling rate: 1000Hz/channel, 10,000Hz for pacemaker detection
  • Input voltage range: ±5mVp-p
  • Time constant: >3.2s
  • Frequency response: 0.05Hz-150Hz
  • Calibration voltage: 1mV±2%
  • Sensitivity: 2.5, 5, 10, 20, 10/5, AGC (mm/mV)
  • Input impedance: >50M Ω
  • Input circuit current: < 10nA
  • Noise level: < 12.5 μ Vp-p
  • Patient leakage current: < 10 μ Vp-p (220V-240V)
  • Patient auxiliary current: < 0.1 μ A (DC)
  • Filters: EMG filter 25Hz/35Hz/45Hz/OFF, Anti-baseline drift 0.05/0.15/0.25/0.5Hz, Low-pass filter 75Hz/100Hz/150Hz, AC filter 50Hz/60Hz
  • CMRR: >115 dB
  • Recording modes: Auto/manual/rhythm
  • Rhythm lead: Single channel or three channels selectable
  • Power supply: AC (100-240V@50/60Hz) 12V Vehicle-Carried Inverter Li-ion Battery
  • Battery: Built-in rechargeable Li-ion battery 2200mAh@14.8V for 6 hours general use or 280 copies EKG / ECGs continuous printing
  • Recorder: Thermal printer
  • Recording paper: 110mm × 140mm × 144P (Z-fold)
  • Recording speed: 5mm/s,6.25mm/s,10mm/s (±3%) 12.5mm/s,25mm/s,50mm/s (±3%)
  • Weight: Approximately 3 kg (including battery and paper)
  • Dimensions: 322m × 310mm × 101mm
  • Display: 5.7" TFT color LCD, 640x480 dots
  • External input: 100K Ω, sensitivity 10mm/V±5
  • External output: 100 Ω, sensitivity 1V/mV±5%
  • Communication interfaces: Ethernet or RS232