EU Cookie Consent

We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read Privacy Policy

Colin BP-S510 Patient Monitor

Colin BP-S510 Patient Monitor

Brand: Colin
Web ID: 1228
Condition: Refurbished
Product Number: 65510

Need help?

Get an Equipment Quote

(800) 462-8195

Biomedical HTM Customers

Service, Repair & Parts

(800) 449-5328

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

Leading-edge patient monitor features patented Colin NIBP technology

The BP-S510 has a sophisticated design that provides simple, user-friendly operation. Its advanced functionality makes it perfect for a wide variety of uses, including post-anesthesia care, ambulatory surgery, endoscopy, emergency rooms and more!

  • Measures — ECG (3/5 lead), heart rate, Colin NIBP, Nellcor SpO2 and respiration. Available with temperature, two-channel IBP, EtCO2, and a printer.
  • Compact — Conveniently compact and feature-packed, the BP-S510 is great for areas where space is at a premium.
  • Lightweight — Weighing only 12.1 lbs, the BP-S510 is easy to carry from ward to ward. This lightweight device makes it easy to move to stepdown, PACU, RR, etc.
  • Battery — Operation for Portability: Available with rechargeable batteries, the BP-S510 can be used during transport within your facility.
  • Wide Viewing Angle — The BP-S510's large LCD screen features a wide viewing angle. Each parameter is color-coded in bright and vivid colors, making the information easy to read even from a distance. You can also select from multiple views to highlight just the information you need.

Specifications

Non-Invasive Blood Pressure (NIBP) - Patented Colin Technology

  • Measurement technology Oscillometric method
  • Measurement method Linear deflation method
  • NIBP Measurement range
  • Adult/pediatric mode:
    • SYS 60 to 250mmHg
    • MAP 45 to 235mmHg
    • DIA 40 to 200mmHg
    • Pulse rate 40 to 200bpm
  • Pressure display range 10 to 300mmHg
  • Pressure display accuracy Less than ±3mmHg
  • Pulse rate 40 to 240bpm
  • NIBP accuracy AAMI SP-10:2002+A1:2003
  • Pulse rate accuracy ±2% or ±2 beats

ECG

  • Leads 3/5 Lead
  • Lead I, II, III, aVR, aVL, aVF, V (Chest Lead)
  • Heart Rate
  • Measurement Range 20 to 250bpm
  • Accuracy ±3bpm or ±5% (whichever is greater)

Respiration (im RR)

  • Measurement method Trans-thoracic impedance
  • Leads RA to LA
  • Range 0, 3 to 120 breaths/min
  • Accuracy ±3 breaths/min

SpO2 (Pulse oximeter)

  • Measurement method 2 wave length pulse wave type
  • Range 1 to 100% SpO2
  • Accuracy Adult/pediatric (When using SpO2 Disposable Sensor MAX-A) 70 to 100% SpO2 ±2 digits, 1 to 69% SpO2 unspecified
  • Pulse Rate Range 20 to 250bpm
  • Pulse Rate Accuracy ±3bpm
  • Display update Less than 30 sec

Temperature Measurement (Optional)

  • Measurement method Thermistor
  • Probe Type Thermistor probe YSI 400 series (2 channels) (Probes not included)
  • Range 15 to 45°C (59 to 113°F)
  • Display Accuracy ±0.1°C (25 to 45°C) (77 to 113°F) ±0.2°C (15 to less than 25°C) (59 to less than 77°F)
  • Probe Accuracy ±0.1°C (±0.18°F)

IBP (Optional)

  • Measurement Method: Pressure Transducer Method
  • Pressure Measurement Range - -50 to +300mmHG
  • Pulse Rate Measurement Range – 20 to 250bpm
  • Display Accuracy - ±3mmHG
  • Standard – IEC60601-2-34:2000

CO2 (Option)

  • Measurement method Non-dispersive Infrared Spectroscopy
  • Range 0-100mmHg : 0-13.3kpa : 0-10%CO2
  • Accuracy ±2mmHg or ±4% (whichever is greater)
  • Respiration (awRR) Range 0 to 120 breaths/min
  • Respiration (awRR) Accuracy ±1 breath/min

Recorder (Option)

  • Type Thermal
  • Weight 0.33 lbs. (150 g)
  • Resolution 8 dot/mm
  • Number of channels 1 to 2 channels
  • Paper Type Thermal
  • Paper Width 2 inches (50 mm)
  • Paper Speeds 25.0mm/sec and 50.0mm/sec (1in/sec and 2in/sec)

Power Requirement

  • AC Power 100-240V~50/60Hz, 0.5-1.3A
  • Battery Ni-MH, 12V/3.8Ah (1 included)

Environmental

  • Operating Temperature 10 to 40°C (50 to 104°F)
  • Storage Temperature -20 to 60°C (-4 to 140°F)
  • Operating Humidity 15 to 90% RH, non-condensing

Accessories & Supplies

Compatible ECG Cables, Leads, & Electrodes

3-Lead ECG Trunk Cable

Web ID: 11812