Criticare nGenuity 8100E Series Patient Monitor

Criticare nGenuity 8100E Series Patient Monitor

Brand: Covidien
Web ID: 11699
Condition: Refurbished

Need help choosing?

Ask an Equipment Expert

(800) 449-5328

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The Criticare nGenuity 8100E Series patient monitor is ideal for monitoring pulse oximetry (SpO2), non-invasive blood pressure, heart rate, temperature, respiration and ECG during conscious sedation or post-procedure recovery. Information can easily be read on the crisp 10.4 inch color display, while dedicated function keys allow for quick setup and easy use under demanding time constraints. Full compatibility with popular Electronic Medical Records (EMR) systems makes it easy for any facility or office to transfer patient data.

With a compact, lightweight design and convenient carry handle, the nGenuity 8100E monitor can be wall mounted or quickly attached to a rolling stand for easy transportation within any medical setting. For increased portability, the sealed battery can be recharged with a standard AC plug or powered directly from AC power to eliminate the need for a special adaptor. Request a quote or learn more about the nGenuity 8100E patient monitor by speaking with an Avante equipment specialist today.

Features

  • Monitors pulse oximetry (SpO2), non-invasive blood pressure, heart rate, temperature, respiration and ECG.
  • Easy to read 10.4 inch color display with mini-trends display of condensed tabular vital signs data.
  • Large, membrane style keys and a simplified user interface allow fast spot checking and easy control of the monitor’s on-screen menu selection.
  • Compact and lightweight design that can easily be carried, wall mounted or quickly attached to a rolling stand.
  • Compatible with popular Electronic Medical Records (EMR) systems for both large and small offices.
  • Proprietary ComfortCuff NIBP by Criticare which measures on inflation for a faster, more comfortable reading.

Specifications

ECG

  • Number of Leads: 3 – or 5 Lead
  • Lead View: User-selectable; I, II, III, aVR, aVL, aVF, V (5-Lead); I, II, or III (3-Lead)
  • Gain Selection: x0.5, x1, x2, and x4
  • Frequency Response: Diagnostic: 0.05 to 100 Hz (-3dB);
  • Monitor: 0.5 to 40 Hz (-3dB);
  • ST: 0.05 to 40 Hz (-3dB
  • Electrosurgery: Yes
  • Defibrillator Protection: Yes
  • Pacer: Yes
  • ST Accuracy: ±0.2 mm or ±5% of reading, whichever is greater, over heart range of 30 to 120 bpm
  • ST Range: -6.0 to 6.0 mm

NIBP

  • Technique: Oscillometric measure upon inflation
  • Inflation Range: Adult/Pediatric: 0 to 300 mmHg: Neonate: 0 to 150 mmHg
  • Measurement Cycle: < 40 sec. typical; standard adult cuff
  • Auto. Measurement: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hour intervals
  • STAT Mode: 5 minutes of consecutive readings
  • Maximum Cuff Pressure: Adult/Pediatric: 300 mmHg; Neonate: 150 mmHg
  • Resolution: 1 mmHG
  • Transducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater, over full range
  • Clinical Accuracy: Complies with AAMI

Pulse Oximetry

  • Range: 1% to 99%
  • Resolution: 1%
  • Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspecified
  • Method: Dual wavelength LED

Heart Rate (Pulse)

  • Source: User selectable: Smart, ECG, Pleth, NIBP, IBP
  • Range: 20 to 300 bpm (ECG, Pleth); 30 to 240 bpm (NIBP); 30-300 bpm (IBP)
  • Accuracy: ±1 bpm or ±1% (ECG) whichever is greater

Temperature

  • Channels: 1
  • Probe: YSI-400 and YSI-700 Series
  • Range, Accuracy: 68° to 113°F (20° to 45°C): ±0.1°C
  • Display Resolution: 0.1°C

Respiration

  • Rate 6 to 150 bpm (ECG); 2 to 120 (CO2)
  • Resolution: 1 breath/min
  • Accuracy: ±1 breath/min
  • Source: User selectable: Smart, CO2, ECG-TTI

Capnography

  • Units: mmHg; kPa; Torr; Percent
  • Method: Non-dispersive infrared; autocalibrating
  • N2O Compensation: Manual (On/Off, user selectable
  • Range: 0 to 99 mmHg; 0 to 12.5%;
  • Flow, Sample Rate: Sidestream; 200 ml/min
  • Accuracy: ±2 mmHg, ±0.3 volume %, ±0.3kPa, or ±2 Torr at 200 ml/min and respiratory rate equal or less than 120 bpm
  • Rise Time: 170 ms (10 to 90%) at 200 ml/min

IBP

  • Channels: 1 or 3
  • Transducer Sites: Selectable: ART, PA, LV, RV, LA, RA, CVP, ICP
  • Pressure Range: -10 mmHg to 300 mmHg
  • Transducer Frequency: 0 to 20 Hz; Impedance >300 ohms; Transducer
  • Sensitivity: 5µV/V/mmHg
  • Accuracy: ±1 mmHg or ±1%, whichever is greater

Alarms

  • Indication: Audible; Visual
  • Silence: Yes; 2 minutes or permanent

Trends

  • Memory: 24 hours at 30 second intervals with a NIBP reading every three minutes
  • Display: Tabular, Graphical

Interface & Display

  • Keys: 9; membrane activated
  • Rotary Knob: Push and rotate; 24 steps/turn
  • Screen: 10.4 inch active color TFT
  • Resolution: Internal Display: 640 x 480; External VGA Display: 640 x 480
  • Waveforms: 6, maximum
  • Waveform Types: ECG Leads I, II, III, aVR, AVL, AVF, V; Respiration; CO2; Pleth; ST Histograms
  • Sweep Speed: 6.25, 12.5, 25, or 50 mm/sec
  • Languages: English, Czech, French, German, Italian, Polish, Portuguese, Russian, Spanish, and Turkish

System Outputs

  • Nurse Call: Contact switch; 3.5 mm phone jack, 14 mm length
  • COM Port: RS232 compatible, DB9 (Com 1)
  • Defib/Sync: BNC connector
  • Video Port: High density D-sub 15-pin serial VGA compatible

Physical Properties

  • Weight: 14 lbs; 6.4 kg
  • Size: 11 in (H) x 13 in (W) x 10.3 (D); 28 cm (H) x 33 cm (W) x 26.2 cm (D)

Power Requirements

  • Voltage: 100 to 240 VAC; 50/60 Hz
  • Power Consumption: 35 Watts, typical
  • Battery: 1 sealed lead acid
  • Battery Life: 3.0 hours, typical (2.5 hours w/CO2
  • Recharge Time: 4.5 hours, typical

Environmental

  • Operating Temperature: 59° to 95°F (15° to 35°C)
  • Storage Temperature: 23° to 122°F (-5° to 50°C)
  • Operating Humidity: 15% to 90%, noncondensing

Classification

  • Medical Device: Class II Equipment (IIb EU)
  • Electrical Protection: Class I Equipment
  • Degree of Protection: Type CF, Defibrillator-proof
  • Protection Against Ingress: IPX1
{