EU Cookie Consent

We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read Privacy Policy

Criticare Scholar EL Multi-Parameter Monitor

Criticare Scholar EL Multi-Parameter Monitor

Brand: Covidien
Web ID: 954
Condition: Retired

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Biomedical HTM Customers

Service, Repair & Parts

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

Features

  • Up to ten vital parameters in one system with central station capability
  • Battery back up
  • Interactive, user-friendly data card technology
  • ESI suppression, pacer rejection and defibrillator protection

Specifications

Physical Weight & Dimensions

  • Height: 16.5 cm (6.5 in)
  • Width: 34.3 cm (13.5 in)
  • Depth: 30.5 cm (12 in)
  • Weight: 5.5 Kg (12 lbs) typical

ECG

  • Number of Leads: 3 or 5 lead wire cables
  • Lead Selection: I, II, III, a VR, aVL, aVF, V (5 wire cable)
  • Gain Selection: ½mV, 1mV, 2mV, 4mV, 8mV full scale (all± 2%)
  • Frequency Response: Diagnostic: 0.05-100 Hz (-3dB); Monitor: 0.5-40 Hz (-3 dB)
  • Sweep Speed: 6.25, 12.5, 25, 50 mm/sec

Heart Rate Display Alarms

  • User Selectable Choices: Primary: ECG; Choices: ECG, Pleth, ART, PA, PW
  • Range: 20-300 BPM
  • Update Time: Every beat
  • Accuracy: ± BPM
  • Alarm Limit Range: 80-300 BMP (high); 20-150 BPM (low)

Non Invasive Blood Pressure

  • Technique: Oscillometric during inflation
  • Max Inflation Pressure: Adult 300 mmHg; Neonate: 150mmHg
  • Measurement Cycle: <40 second average (0-300 mmHg: adult cuff)
  • Automatic Measurement Cycles: 1, 3, 5, 15, 30, 60 minutes

Invasive Blood Pressure (Optional)

  • Number of Channels: 4
  • User Selectable Labels: ART, PA, ICP, CVP, PW
  • Isolation: 4kV RMS, 5.5 kV peak from ground related currents
  • Pressure Range: -10 mmHg to 300 mmHg
  • Zero Offset: ±150 mmHg
  • Probe Impedance: 300-2500 input ohms
  • Frequency Response: 0-20 Hz
  • Input Impendence: 820K @ 20 Hz; >100M @ DC
  • Transducer Sensitivity: 5µV/V/mmHg
  • Zero: Auto push button
  • Drift: ±1 mmHg
  • Accuracy: ±1 mmHg
  • Scale Range: -10 to 10, 0 to 20, 0 to 40, 0 to 60, 0 to 100, 0 to 150, 0 to 200, 0 to 300
  • Display: Systolic, diastolic, mean pressure

Impendance Respiration

  • Rate: 0-150 breaths/minute
  • Resolution: 1 breath/minute
  • Accuracy: > of ±1% or ±1 breath/minute

Alarms

  • Alarm Indication: Audible, visual
  • Alarm Silence: Yes (2 minutes, or permanent)

Temperature (Optional)

  • Number of Channels: 2
  • Range: 20-45° C (68-113° F); ±0.5° C (20-34° C); ±0.2°C (34-41°C); ±0.5°C (41-45°C)
  • Display Resolution: 0.1°C or 0.1°F

Oxygen Saturation

  • Averaging Time: Selectable 3-21 seconds
  • Search Time: Selectable, 1-40 seconds
  • Waveform: User selectable
  • Gain: User selectable
  • Audio: Beep with each detected pulse, pitch varies with oxygen saturation
  • Range: 1-99%
  • Resolution: 1%
  • Accuracy: ±2% (70-99%); ±3% (50-70%)
  • High Saturation Alarm: Range: off, 70-99%
  • Low Saturation Alarm: Range: off, 1-99%

Accessories & Supplies

Compatible ECG Cables, Leads, & Electrodes

3-Lead ECG Trunk Cable

Web ID: 11812