EU Cookie Consent

We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read Privacy Policy

GE AMX-III Portable X-Ray Machine

GE AMX-III Portable X-Ray Machine

Brand: GE
Web ID: 936
Condition: Refurbished

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

Features

  • MX-75 275k HU X-ray tube with a .75 mm focal spot
  • LED display
  • 24 kVp stations
  • 28 mAs stations
  • 100 mA constant
  • kVp 50 - 125
  • mAs 0.64 – 320

Warranty

  • Eighteen-month warranty on all parts.
  • One-year prorated warranty on the X-ray tube. For warranty purposes, X-ray tubes are valued at $1,500.
  • Two-year manufacturer's warranty for the lead calcium batteries (the first year they are fully covered and the second year is prorated).

Specifications

Power Requirements

Obtained from rechargeable 120V battery

Power Required to Recharge Battery

110 to 125 VAC, 50/60 Hz, 6.0 amps

Battery Capacity

Approximately 10,000 mAs at 100 kVp, when fully charged

Motor Drive Ratings

The drive assist unit can be driven at speeds up to 180 feet per minute or 54.9 meters per minute

X-ray Generator Ratings & Duty Cycle

All radiographic exposures with this unit are at 100 milliamperes

kVp (maximum)

  • 110 to 125
  • 95 to 105
  • 50 to 90

mAs (maximum)

  • 200
  • 250
  • 320

All rates and duty cycles are subject to limitations of the X-ray tube rating and apply at altitudes up to 8,000 feet (2,438 kilometers), average relative humidity not exceeding 80% and ambient temperature between 60°F (15.6°C) and 100°F (37.8°C)

Typical Accuracies

±6% of kVp and ±10% of mAs

Selection and Range

  • 0.64 mAs to 1.25 mAs
  • 1.6 mAs to 10 mAs
  • 12.5 mAs to 320 mAs
  • 50 kVp to 74kVp
  • 76 kVp to 125 kVp

Accuracy

  • ±30%
  • ±20%
  • ±12%
  • ±(9% + 1kV)
  • ±(12% + 2 kV)

kVp accuracies subject to additional ±(5% + 2kV) and mAs to ±3% accuracy of instrumentation used for calibration and measurement.

Conditions to Meet Previously Mentioned Accuracies

  • Handswitch must have been released for 25 seconds after previous exposure.
  • 15-minute interval after change completion with keyswitch in ON or CHARGE.
  • Main power circuit breaker ON must be allowed before making an exposure

Collimator

  • Minimum inherent filtration is 1.5 mm aluminum equivalent to 150 kVp. Additional filtration may be obtained by inserting 1 mm and/or 2 mm aluminum filters.
  • Minimum source-to-skin distance is limited to more than 30 cm by the tracks on the bottom of the collimator for mounting the accessory extension cylinder.
  • Full 17" x 17" (.43 m x .43 m) radiographic coverage at 40" (1.02 m) source to image distance is provided for tubes with a 15-degree target angle.
  • Collimator can be rotated and locked positively at 0°, ±15°, ±30°, ±45°, and ±90° from the front position.