EU Cookie Consent

We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read Privacy Policy

GE Optima XR220amx Digital X-Ray System

GE Optima XR220amx Digital X-Ray System

Brand: GE
Web ID: 13806
Condition: Refurbished

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The GE Optima XR220amx is a digital mobile x-ray system that allows technicians to perform exams when and where they’re needed. The wireless digital detector provides the functionality, image quality, and productivity of a radiographic room at the point of care, which makes this x-ray system ideal for patients in situations where is is dangerous or impractical to move them to a RAD room.

The GE Optima XR220amx is available refurbished through Avante Health Solutions. For more information, contact an Avante representative today.

Features

  • Battery operated
  • Dual-motor drive
  • Self-stopping bumper
  • Dose area product meter
  • Hand switch
  • Extendable telescopic arm for tube placement
  • Display, technique, and image acquisition tools in single integrated user interface
  • Lightweight digital detector enclosure, designed for mobile use
  • Attachable tether and detector holder for digital detector
  • Allows technicians to make and process exposures while unit is charging
  • Stand-by mode eliminates boot up cycles, allows exposures within 25 seconds
  • Tablet holder (optional)
  • Remote switch (optional)
  • Barcode scanner (optional)

Specifications

Power

  • Capability of 100-240 V nominal
  • 50/60 Hz
  • Power consumption: 1440 VA

X-ray tube

  • Nominal voltage (radiographic): 40 to 150 kV
  • Anode rotation speed (minimal): 3200/min
  • Nominal Focal Spot size (IEC 60336):
    • Large Focus: 1.2
    • Small Focus: 0.6
  • Maximum X-ray Tube Current:
    • Large Focus: 500 mA
    • Small Focus: 200 mA

Tube positioning

  • May be rotated ±270° from park position
  • Maximum focal spot height: 200 cm (78.7 in)
    • Short column configuration maximum focal spot height: 62.5 cm (24.6 in)
  • Minimum focal spot height: 62.5 cm (24.6 in)
  • Vertical travel 137.5 cm (54.1 in)
    • Short column configuration vertical travel: 122.2 cm (48.1 in)

High-voltage generator

  • Power (kW): 15 standard, 30 optional
  • mA: 300 maximum
  • Minimum exposure time: 4.0 msec

Collimator

  • Rotation: ±180°
  • Detents at -180, -90, 0, +90, and +180°
  • Full 43 cm x 43 cm (17 in) coverage at a 100 cm SID

Digital detector

  • Can support up to 160 kg (352 lbs) of distributed load
  • Length: 58 cm (23.1 in)
  • Height: 45.2 cm (17.8 in)
  • Width: 2.4 cm (0.94 in)
  • Detector weight: 4.53 kg (9.9lbs)
  • Battery weight: 0.18 kg (0.39lbs)
  • Tether Length: 4m
  • Image area: 40.4 cm x 40.4 cm (15.9 in x 15.9 in)

Dimensions

  • Overall Width (including front bumper): 55.9cm (22 in)
  • Overall Height: 194 cm (76.3 in)
  • Overall Length: 124.6 cm (49.1 in)
  • Weight: 453 kg (1,000 lbs.) max