GE Precision 500D Radiology & Fluoroscopy Room

GE Precision 500D Radiology & Fluoroscopy Room

Brand: GE
Web ID: 17241
Condition: Refurbished

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The GE Precision 500D is a digital radiography and fluoroscopy system. This PC-based system is designed to replace conventional fluoroscopic techniques. It provides exceptional image quality at a lower dose, and helps increase patient throughput and clinical productivity.

The GE Precision 500D is available professionally refurbished through Avante Health Solutions. Contact an Avante representative today for more information.

Features

  • Allows you to view 1024 x 1024 images upon acquisition
  • High resolution image monitor
  • Image viewing includes computerized window, subtraction, inversion, edge enhancement, level, and magnification features to help you find details that are traditionally difficult to see
  • Wide dynamic range
  • Can print images to traditional film output devices
  • Archive images using a variety of devices
  • User-friendly interface
  • Advanced dose-management features
  • 12-bit CCD-based camera
  • Closed-loop automatic brightness control
  • Automatic last-image-hold
  • Special filtration to minimize absorbed dose during fluoroscopy
  • Digital spatial filters optimize radiographic image quality
  • Virtual collimation to gauge collimator position without extra exposures
  • Controls grouped by frequency of use for quick access

Specifications

Table

  • Longitudinal Travel: 60” (152.4 cm)
  • Longitudinal Travel (either side of center): 30” ± 0.75” (76.2 cm ± 1.9 cm)
  • Lateral Travel (either side of center): 3.88” ± 0.12” (9.85 cm ± 0.3 cm)
  • Power: 240VAC, 20 amps, Single phase, 50/60 Hz
  • Max. Patient Load - No Movement or Tilt: 500 lb. (226 kg)
  • Max. Patient Load - With Movement and/or Tilt: 300 lb. (136 kg)
  • Max. Patient Load - Under Table Patient Step: 450 lb. (204 kg)

X-Ray Tube

  • MX 100 FL
  • Target Angle: 12.5°
  • Focal Spot: 0.6 mm/1.25 mm
  • Power: 32/100 KW
  • Shim: 2.1°

OTS Radiographic Suspension

  • Longitudinal Focal Spot Travel: 108.54” (275.7 cm)
  • Lateral Focal Spot Travel: 47.24” (120 cm)
  • Vertical Focal Spot Travel: 59” (150 cm)
  • Horizontal Tube Rotation: ± 180 degrees; detents at each 90 degree position
  • Vertical Tube Rotation: + 110/-20 degrees
  • Focal Spot to Ceiling Distance (Horizontal): 28.86” - 87.87” (73.3 - 223.2 cm)
  • Focal Spot to Ceiling Distance (Vertical): 28.07” - 87.05” (71.3 - 221.1 cm)
  • Minimum Overall Room Dimension, Front to Back, without Modifying Basic Structure: 10.5 ft (3.2 m)
  • OTS Suspension Weight: 500lbs (431kg)

Collimator

  • Dimensions(L x W x H): 13.74” x 9.33” x 7.12” (34.9 x 23.7 x 18.1 cm)
  • Weight: 21.6 lbs ± 1.1 (9.8 kg ± 0.5)
  • Aperture Angle: 28° / 28°
  • Angle of Rotation around central beam axis: ±45°