Respironics Tidal Wave 615 Handheld CO2 Monitor

Respironics Tidal Wave 615 Handheld CO2 Monitor

Brand: Respironics
Web ID: 925
Condition: Retired

0 item is in your cart. View cart now

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Biomedical HTM Customers

Service, Repair & Parts

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

DRE offers the Respironics Novametrix Tidal Wave model 615 portable handheld pulse oximeter and CO2 monitor with SpO2. The Tidal Waves are the only handheld, mainstream capnographs available today, and provide immediate feedback on the patient's airway condition and ventilatory status. Based on the same technology as Respironics Novametrix bedside capnographs.

Three Optional Configurations

  • Tidal Wave Model 610 Handheld Mainstream Capnograph
  • Tidal Wave Model 615 (described on this page) Handheld Capnograph with Mainstream and Sidestream Sampling
  • Tidal Wave Sp Model 710 Handheld Mainstream Capnograph/Pulse Oximeter Tidal Wave Sp
  • Tidal Wave Sp Model 715 Handheld Mainstream Capnograph/Pulse Oximeter with Sidestream Sampling Capabilities

Features

  • Built in Pulse Oximeter
  • Hand-held Mainstream and Sidestream Capnograph
  • 30-minute on-screen graphic trend available
  • Visual and audible "no respiration" alert
  • User replaceable disposable and rechargeable battery packs eliminate the need to wait while batteries are charging (standard AA lithium: 5.5 hours of life)
  • No calibration required for CO2

Specifications

Capnograph

Principle of Operation

Solid state mainstream sensor. Single beam, non-dispersive infrared (NDIR) absorption, ratiometric measurement.

Initialization Time

Capnogram within 15 seconds, full specifications within 60 seconds.

Calibration

No calibration required.

Capnostat® Mainstream CO2 Sensor

  • Size: 3.30 × 4.24 × 2.16 cm (1.30 × 1.67 × 0.85 in.)
  • Weight: 18 grams (0.64 oz.), cable excluded
  • Shock Resistance: Withstands repeated six foot drops to a hard surface.

CO2 (Carbon Dioxide)

  • Range: 0 - 150 mmHg
  • Accuracy:
    • ±2 mmHg (for 0 - 40 mmHg),
    • ±5% of reading (for 41 - 70 mmHg),
    • ±8% of reading (for 71 - 150 mmHg)
  • Resolution: 1 mmHg
  • Response Time: 60 ms
  • Units: mmHg, kPa, or %
  • Compensations: N2O & O2 (selectable), Pb (automatic)
  • Capnogram: Selectable sweep speed

Respiratory Rate

  • Accuracy: ±1 br/min
  • Range: 0-150 br/min
  • Resolution: 1 br/min

Sampling Flow Rate (715 model only)

  • 180 ml/min (for non-intubated patients)
  • Response time is less than 200 ms at 180 ml/min flow

Pulse Oximeter

Principle of Operation

Red/Infrared absorption.

SpO2 (Oxygen Saturation)

  • Range: 0 - 100%
  • Accuracy: ±2% SpO2 (for 80-100% SpO2) (1 SD, or 68% of readings within claim) Unspecified for 0-79% SpO2
  • Resolution: 1%
  • Averaging: Menu selectable 2 or 8 seconds

Pulse Rate

  • Range: 30-250 bpm
  • Accuracy: ±1% of full scale
  • Resolution: 1 bpm
  • Averaging: 8 seconds

Sensors

Reusable Y-Sensor (can be sterilized and used with all patient populations); reusable adult finger sensor

General

Alerts

  • Limits: Adjustable limits for ETCO2, SpO2, Respiratory Rate and Pulse Rate. No Respiration Detected adjustable timeout.
  • Audio: Adjustable volume, two minute silence or off (LED indicators)
  • Visual: On-screen and LED

Display

  • Type: Dot matrix, backlit (LCD)
  • Size: 2.2 × 1.1 inches

Trending Capabilities

  • Memory: 24 hr., battery backed
  • Format: 30 minute on-screen or printed in trend or tabular mode.
  • Download data to personal computer for use with NovaCARD software.

Communication Output

RS232 to Seiko DPU-414 printer, NovaCARD software or computer

Physical Weight & Dimensions

  • Height: 8 inches (20 cm)
  • Width: 3.75 inches (8.5 cm)
  • Depth: 1.875 inches (4.8 cm)
  • Weight: 793 grams (28 oz.)

Electrical

  • External Supply: Optional
  • Input: 120 VAC 60 Hz, or 220 VAC 50 Hz
  • Battery: Nickel-Metal-Hydride (NiMH): 4.5 hour life
  • Battery: Standard AA lithium: 5.5 hour life

Environmental

  • Operating temperature: 0 to +40 °C (32-104 °F)
  • Operating humidity: 0 to 90% RH non-condensing

Accessories & Supplies

CO2 Cannulas

View all

CO2 Sampling Cannula with Split O2 Delivery

P04092D - Male Luer, P03082D Female Luer

Web ID: 453