Welch Allyn AED-10 Desfibrilador Externo Automático

Welch Allyn AED-10 Desfibrilador Externo Automático

Marca: Welch Allyn
Web ID: 52
Condición: Retired

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Términos y Condiciones del Listado

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

Nueva Welch Allyn AED 10 (anteriormente conocido como el JumpStart de MRL) es ligera y móvil con la salida de energía biphasic. La voz y visual apunta toman a un usuario por un proceso de defibrillation de tres pasos proporcionando la grabación de acontecimiento continua. La unidad realiza una autoprueba semanal y tiene la protección de bloqueo para prevenir defibrillation involuntario.

Specifications

General

  • Height: 8.25 inches (210 mm)
  • Width: 6.875 inches (175 mm)
  • Depth: 2.75 inches (70 mm)
  • Weight: 3.5 lbs with battery (1.6 kg)
  • Operating Temperature: 0° to 50°C
  • Storage Temperature: -30° to 70°C (without battery)
  • Humidity: Up to 95% or 10° to 95°C (non-condensing)
  • Altitude: Up to 15,000 feet (-150 to 4570 m)
  • Shock: Mil Std 810E method 516.4, procedure 1 (40G, 6-9 ms pulse, 1/2 sine each axis)
  • Vibration: Mil Std 810 method 514.4, category 1
  • Water resistance: IEC 529 IPX4
  • Drop Test: Mil Std 810F method 516.5 Procedure IV (1 meter drop onto any edge, corner, or surface)

Defibrillator

  • Output: Welch Allyn Orbital™ Biphasic Truncated exponential
  • Energy Select: 200, 300, 360J or user configurable among the energy options: 150, 200, 300, 360
  • Charge Time: Less than 5 seconds to 150J, less than 15 seconds to 360J
  • Analysis Time: 4-16 sec
  • Audible Prompts: 18 audible prompts
  • Visual Prompts: 20 text screen prompts
  • Controls: Four buttons - On/Off, Shock, and 2 software configurable buttons
  • Accuracy: ±10% or 1J (whichever is greater) at 50.

Display

  • Size: 54 x 36 mm
  • Type: Backlit monochrome LCD
  • Display Resolution: 160 x 100 pixels
  • Low Battery Indicator: Battery Icon gauge on display with 10 capacity levels
  • Backlight: LED

Battery

  • Non-Rechargeable: LiMnO2 12V, 2.6 Ah
  • Capacity: 90 discharges at 360 Joules or 125 discharges at 200 Joules or 150 discharges at 150 Joules or 5 hours ECG monitoring
  • Shelf Life: (25°C±15°C) 10 years (5 years storage + 5 years standby); 5 years standby (after installation). Capacity may be diminished at operating temperature extremes.

Electrical Isolation

  • Power: Unit operates on internal battery only
  • External Electrical Connections: No external devices are attached to the unit
  • Risk Current Category: Class II equipment with defibrillator-proof BF type patient applied parts (as per definition of IEC 60601-1 standard.)

Electromagnetic Compatibility

  • Radiated Emissions: EN55011; CISPR11 BESD: EN61000-4-2; 8KV air 6KV contact
  • Radiated Susceptibility: EN61000-4-3 (10 V/M (20 v/m EN60601-2-4))
  • Magnetic Field Emissions: MIL STD RE101 (AAMI DF 24.3.18.1)
  • Magnetic Field Susceptibility: MIL STD RS101 1 Gauss, 47 Hz-1.8 KHz

Electrical Isolation

  • Radiated Emissions: EN55011; CISPR11 BESD: EN61000-4-2; 8KV air 6KV contact
  • Radiated Susceptibility: EN61000-4-3 (10 V/M (20 v/m EN60601-2-4))
  • Magnetic Field Emissions: MIL STD RE101 (AAMI DF 24.3.18.1)
  • Magnetic Field Susceptibility: MIL STD RS101 1 Gauss, 47 Hz-1.8 KHz

Data Management

  • Event Documentation: Internal
  • Internal Memory Capacity: 1MB: 250 4-sec ECG samples or 3000 time stamped events
  • Quick Report: Treatment Summary, Event Log, Test Log
  • Communication: RS-232 via Infrared (IR) port to PC or printer