EU Cookie Consent

We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read Privacy Policy

Drager Savina Ventilator

Drager Savina Ventilator

Brand: Drager
Web ID: 1292
Condition: Refurbished

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The advanced Dräger Savina ventilator is easy to use and versatile

The dependable Dräger Savina can help you face clinically challenging environments. It is easy to use and combines excellent ventilation performance, quality and versatility.

  • Helps minimize risk to the patient
  • Adapts to altering needs with ease
  • Can support weaning
  • Promotes long-term ventilation and recovery

Ventilation performance that is excellent and flexible

  • With its open breathing system, the Savina enables spontaneous breathing at any time and any pressure level in all ventilation modes during ventilation cycles
  • Features an internal turbine that removes the need for air cylinders or an external compressor
  • Navigate power failures and support mobility with an internal battery
  • Multiple ventilation modes accommodate various acuity levels and patient populations

High quality; includes safety concept

  • Precise, endurable O2 dosage enabled by nine rubies
  • Independent, unseen "bodyguards" for improving safety for the patient, and backup twin sensors for airway pressure, FiO2 and minute volume

Design promotes easy use

  • Access to key settings for ventilation
  • Minimized training time via an intuitive operating concept
  • Color screen is bright and high res for high visibility, from up close and a long range
  • Attractive in most clinical environments

Specifications

Ventilation Mode

PPV (CMV), IPPVAssist (CMVAssist), SIMV, SIMVASB (SIMV/PS) CPAP, CPAPASB (CPAP/PS), BIPAP* (PCV+) (optional) BIPAP* ASB (PCV+/PS) (optional)

Enhancements

  • NIV - Non Invasive Ventilation with optimized alarm system and automatic leakage compensation (optional)
  • AutoFlow® - Automatic adaptation of the inspiratory flow in volume orientated ventilation modes (optional).
  • LPO - Low Pressure Oxygen. Independent oxygen supply, e.g. with an O2 concentrator (optional)
  • Graphic screen - Advanced ventilation monitoring (optional)
  • Nurse call - Connection for transmitting alarm signals to a central alarm system (optional)

Patient Type

Adult, pediatric

Ventilation Frequency

2 to 80 bpm

Tidal Volume

0.05 to 2.0 L, BTPS**)

Inspiratory Flow

0 to 180 L/min

Inspiratory Pressure

0 to 99 mbar***) (cmH2O)

PEEP/Interm. PEEP

0 to 35 mbar (cmH2O)

Pressure Support/ASB

0 to 35 mbar (cmH2O) (relative to PEEP)

Flow Acceleration

5 to 200 mbar/s (cmH2O/s)

O2-Concentration

21 to 100 Vol. %

Trigger Sensitivity

1 to 15 L/min

Measured Value Display

  • Airway pressure measurements: Peak pressure, plateau pressure, mean airway pressure, PEEP 0 -100 mbar (cmH2O)
  • Minute volume (MV): Total MV, spontaneous MV 0 to 99 L/min, BTPS
  • Tidal volume VT: Inspiratory VT, expiratory VT 0 to 3999 mL, BTPS
  • Breathing frequency: Total and spontaneous breathing frequency, 0-150 bpm
  • Inspiratory O2-concentration: 21 to 100 Vol. %
  • Breathing gas temperature: 18 to 48°C (sensor optional)
  • Curve displays: Airway pressure / time, flow / time
  • Ventilation ratio (I:E): 150:1 to 1:150

Alarms

  • Airway pressures: High / low
  • Expiratory minute volume: High / low
  • Tidal volume: High / low
  • Apnoea-alarm time: 15 to 60 sec
  • Spontaneous breathing frequency: High
  • Inspiratory O2-concentration: High / low
  • Inspiratory breathing gas temperature: High

Performance Data

  • Maximum flow for pressure assist/spontaneous breathing: 180 L/min
  • Valve response time T0…90: ≤ 5 ms
  • Control principle: Time-cycled, volume-constant, pressure-controlled
  • Safety valve opening pressure: 100 mbar (cmH2O)
  • Emergency valve: Automatically enables spontaneous breathing with filtered ambient air if air and O2 supply should fail
  • Automatic gas switch-over function if O2 supply fails
  • Output for pneumatic medicament nebuliser: Synchronized with inspiration

Operating Data

  • Main power connection 100 V to 240 V, 50/60 Hz AC, 10 to 36 V DC
  • Typical power consumption 100 W
  • Internal battery Approx. 60 min (optional extension up to 7 h)

Digital Machine Outputs

Digital output and input via an RS 232 C interface, Dräger Medibus standard

Gas Supply

  • Air: Turbine technology
  • O2 gas supply: 3 bar (39 psi) to 10 % up to 6 bar (87 psi)

Physical Weight & Dimensions

  • Dimensions (without trolley): 380 (W) × 383 (H) × 358 (D) mm (15.0 × 156.1 × 14.1 inches)
  • Weight (basic device): Approx. 24 kg (53 lbs.)
  • Diagonal screen size: 6.1" TFT color screen
  • * BIPAP – Trademark used under licence
  • ** BTPS – Body Temperature Pressure Saturated. Measured values relating to the conditions of the patient lung, Body temperature 37 °C, steam-saturated gas, ambient pressure.
  • *** 1 mbar = 100 Pa, AutoFlow®, Trademark by Dräger