EU Cookie Consent

We use cookies on this website to provide statistics that help us give you the best experience. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read Privacy Policy

Medfusion 2010i Syringe Pump

Medfusion 2010i Syringe Pump

Brand: Medfusion
Web ID: 1015
Condition: Retired

Need help choosing?

Ask an Equipment Expert

(800) 462-8195

Listing Terms & Conditions

All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.

Details

The Medfusion 2010i syringe pump offers flexibility for a variety of clinical needs, settings and applications. The pump may be utilized whenever meticulous low volume drug on fluid injections using a syringe are required in the hospital.

The 2010i may be field customized for specific applications. A choice of 4 modes of delivery are available: Body Weight Mode, Mass Mode, Continuous Mode and Volume Over Time Mode (dose volume/delivery time). In addition, the pump has the ability to store up to 64 user regimens/protocols. A bolus may be programmed, then changed or administered at any time prior to or during drug delivery.

Features

  • Programmable for four types of infusion - Body Weight Mode; Mass Mode; Continuous Mode; Volume Over Time Mode
  • Ability to store up to 64 user regimens/protocols

Specifications

General

  • Flow rate: 0.01-378.0 ml/hr dependent upon syringe size
  • Bolus rate: up to 378.0 ml/hr dependent upon syringe size
  • Total Volume Delivered: 0.0000-9999 mg. ml or units
  • Accuracy: ±3%
  • Infusion Modes: Body Weight, Mass, Continuous and Volume/time
  • Accepts B-D, Monoject and Terumo syringes
  • Accepts: B-D 1 TB, 1, 3, 5, 10, 20, 30, 60 ml Luer lock
  • Monoject 1 TB, 3, 6, 12, 20, 35, 60 ml Luer lock
  • Terumo 1 TB, 3, 5, 10, 20, 30, 60 ml Luer lock
  • B-D (glass) 1, 3, 5, 10 ml
  • Automatically adjusts the output PSI for different syringe sizes
  • Automatically sense syringe size, syringe barrel placement and syringe plunger placement
  • All syringes will fill to their maximum
  • Power: AC-internal battery
  • Recharge Time: No longer than 16 hours with the pump turned off
  • Battery Capacity: at 25C a 16 hour charge will operate the pump for approximately 10 hours at 5.0 ml/hr with a 60 ml syringe
  • At 25 degrees C a 16 hour charge will pump approx. 10 hrs at 5.0 ml/hr with a 60 ml syringe
  • Alarms: Near Empty, Empty, Occlusion, System Malfunction, Low/Depleted Battery, Load Syringe Plunger, Check Clutch, Syringe Pops Out, Invalid Size, Invalid Number, Alarm Audio Volume, soft/loud, Alarm Temporary Delay
  • Status Alerts: Stop/Program, Deliver, Battery In Use, Battery Charging, Priming, Back Light, Standby Mode, Bolus Delivery, End of Bolus
  • Water resistant case
  • Suitable for arterial infusions
  • Weight: 2.5 lbs.
  • 4.5" (w) × 3" (h) × 7.5" (w)
  • Optional 220 volt AC charger makes this syringe usable throughout the world